iM-100 Series FAQs

iM-100series-003

Question
What is the procedure for displaying the "Measure" button?
Answer
Press the "FUNC" button to change the page, so please press until the "Measurement" button is displayed.
Order
003

iM-100series-004

Question
What is the way to see at about 1 meter, but the focus is not good enough? Also, can Transit measure at short distances?
Answer
iM cannot be 1.3m because the shortest focus distance is 1.3m. DT*40LS is 0.5m.
Order
004

iM-100series-006

Question
Is there a pass key (PIN code) by Bluetooh connection?
Answer
If it is a farmware after Ver1.01, it is "1111".
Order
006

iM-100series-007

Question
Is it possible to observe BM?
Answer
Select "Occ.orien" from the coordinate measurement menu. Press [RESEC] in the "Occ.orien". Select "Elevation".
Order
007

iM-100series-010

Question
What is the part number of RS232C cable?
Answer
It is DOC210.
Order
010

iM-100series-012

Question
When importing data from USB, the "JOB" to import is displayed, but where does the "JOB" to import change?
Answer
Select "JOB" in Data Mode.. Select "JOB selection". is displayed.
Order
012

iM-100series-013

Question
Save the downloaded (extension bin) file to USB, and even if you start up, the version upgrade will not start.
Answer
Insert the USB with the power OFF and start while pressing "Shift" and "Lighting Key".
Order
013

iM-100series-014

Question
What is the procedure for observing Z-coordinates?
Answer
Enter the instrument height and visual height by coordinate measurement and observe it.
Order
014

iM-100series-015

Question
Is it possible to edit the coordinates entered? (iM-100 series)
Answer
It cannot be edited, but the coordinates can be deleted and then recreated with the same point name using the key entry.
Order
015

iM-100series-016

Question
At the time of installation, the specified Z coordinates are displayed as (null). Is there not a problem.
Answer
When reading in a file, it seems that it incorporated two -dimensional data. Data of Z coordinates (null) when instrument setup If you use it, coordinate observation and piles will move in two dimensions.
Order
016

iM-100series-017

Question
What is the initialization procedure for all data?
Answer
Turn off the Total Station, press and hold [F1], [F3], and [BS] and release your finger when the power is turned on and the “Memory is clear” is displayed.
Order
017

iM-100series-018

Question
What is the procedure for cutting the Y-axis of the tilt?
Answer
Select "Obs.condition" in Config mode and select "Angle/Tilt". "Tilt crn :Yes(V)"
Order
018

iM-100series-019

Question
Want to erase data, etc. and return to factory defaults.
Answer
For the settings at the time of the factory, press the [F4] key and the [BS] key while the power is turned off, and when the "default setting" is displayed, release the finger from the key. To delete the data, press the [F1] key, [F3] key and [BS] key in the power supply, and release the finger from the key when the "Memory Clear" is displayed.
Order
019

iM-100series-020

Question
Is it possible to store the pin pole prism set in storage?
Answer
The pin pole prism set can be stored.
Order
020

iM-100series-021

Question
How to fix the angle?
Answer
Since "hold" is not assigned by default, it is assigned by "Key setting" in "Settings". Press "Hold" twice to fix the angle, press twice to release.
Order
021

iM-100series-022

Question
Is it possible to read observation data?
Answer
Only coordinate data can be read.
Order
022

iM-100series-025

Question
The distance is displayed with 4 decimal places, what is the procedure to change it to 3 decimal places?
Answer
Set the [EDM] measurement mode to something other than Average.
Order
025

iM-100series-026

Question
Distance values are displayed down to 0.1 mm, and want to display 1 mm.
Answer
The mode is "average precision". The average is calculated and displayed 0.1mm, so set it to a mode other than "precision average" and "high -speed average". It will be 1mm display. * In the case of "tracking", it will be 1cm display.
Order
026

iM-100series-027

Question
To delete on -site data, communication cannot be performed by data output.
Answer
Ensure your output configuration by go to "CNFG" → "Comms Setup" → "RS232C".
Order
027

iM-100series-029

Question
The name 1.31 does not appear in the site details.
Answer
"." Dot or "/" slash cannot be entered.
Order
029

iM-100series-030

Question
"Why does the number of data in the "JOB selection" list not match the number of data in the output data?
Answer
"JOB selection" The number of data in the list is the number of all data registered, including coordinate data and observation data, and the number of points does not match because only coordinates are output for the output data.
Order
030

iM-100series-031

Question
After setting the instrument point in "Resection", is it necessary to zero the angle before "Coordinates Setting-out"?
Answer
This is unnecessary because the set orientation angle will be set to zero.
Order
031

iM-100series-034

Question
What is the difference between the target height and the sight height in the REM display on the pile driving observation screen?
Answer
The goal is the height from the ground you want to see in REM measurement, and the visibility is high prism.
Order
034

iM-100series-038

Question
Coordinate data has been deleted, but the number of records in the field displayed on the job selection screen does not decrease.
Answer
Due to the internal file system of the instrument, the total number of records displayed does not decrease even if the data is deleted.
Order
038

iM-100series-039

Question
What is the procedure for coordinate observation?
Answer
Start collecting coordinate by going to "TOPO" → "COOR". Ensure that the Occupy and BS data have been already been configured.
Order
039

iM-100series-040

Question
The coordinates measured but the elevation is <NULL> displayed. (iM-100 series)
Answer
The elevation of the instrument point coordinates <NULL> is . <NULL> , coordinate measurements do not calculate elevation.
Order
040

iM-100series-041

Question
To display horizontal distance instead of slant distance
Answer
Enter the setting screen in [Settings] → [Observation Conditions] → [Distance], and change the "distance display" to "horizontal distance".
Order
041

iM-100series-042

Question
Is there a setting for the distance display of the scale factor?
Answer
The distance display is required to switch horizontal distance. The flat distance is considered to be the scale factor, and the site distance does not take into account the scale factor.
Order
042

iM-100series-043

Question
What is the procedure for setting the scale factor?
Answer
Please set the scale factor in the job management -on -job details.
Order
043

iM-100series-044

Question
The average precision is set to 3 times, but the distance is displayed with 4 decimal places. Is it possible to display 3 digits? (iM-100 series)
Answer
Not possible.
Order
044

iM-100series-045

Question
In the settings, observation conditions, and distance, the result display on the average precision is 0.1mm display, even though it is set to "distance display: 1mm". (iM-100 series)
Answer
The precision average result display is 0.1mm display fixed.
Order
045

iM-100series-046

Question
After entering all the measurement points, can I skip the points that I don't want measure and proceed to the next point of measurement?
Answer
When batch input is selected, it is not possible to skip a point, so either redo the observation or proceed to the next point with angular measurements.
Order
046

iM-100series-047

Question
During the surveying work, a version upgrade was announced.
Answer
Keep the message off and continue working on it. After returning to the office, please upgrade the software
Order
047

iM-100series-048

Question
Is it possible to switch between 0 degrees zenith and 0 degrees horizontal? (iM-100 series)
Answer
It can be switched in "V Mode" under "Settings, Observation Conditions, Angle/Tilt".
Order
048

iM-100series-049

Question
When power is turned off, the RUTE data is lost. What should be done?
Answer
Select "Inst.Config" in Config mode and select "Power supply". Select "Resume :On". When the Resume function is set to "On" and the power is switched off and then on again, the screen appearing before the instrument was switched off, or a prior screen is redisplayed.
Order
049

iM-100series-050

Question
What features are included in the equipment?
Answer
These include coordinate meas., setting-out mea., topography obs., offset mea., missing line mea., surface area calc., intersections, traverse adjustment, rote surveying, etc.
Order
050

iM-100series-052

Question
What is the procedure for setting an arbitrary angle?
Answer
Press [H-SET] on the second page of the OBS mode and select "Angle."
Order
052

iM-100series-055

Question
Is it possible to see the height difference between the instrument and the prism on the standard measurement screen? (iM-100 series)
Answer
In the first page of OBS mode, press [MEAS] to start distance measurement. A short beep sounds, and the measured distance data are displayed. Press [STOP] to quit distance measurement. Each time [SHV] is press, SD, HD, and VD are displayed alternately.
Order
055

iM-100series-059

Question
Please tell me how to enter the offset for the alignment of a route(3Pt. Curve)?
Answer
Press [MENU] on the third page of the OBS mode to enter the Route Calculation menu. Select "3PT Curve" to enter the 3 point calculation menu. Input the all data and St. ofs'BP Point offset).
Order
059

iM-100series-060

Question
Can the battery BDC72 be used in the iM-100 series instead of BDC70?
Answer
Can be used. The charger for BDC72 is CDC77.
Order
060

iM-100series-061

Question
After starting up the iM-100 series, when you close the Tilt screen, "0 Set", "Take F1", and "ZA V1" are displayed.
Answer
When "V manual " is set to "Yes", the display appears "0 Set" screen.
Order
061

iM-100series-062

Question
Is there a curve radius input limit for the iM-100 series of route calculations?
Answer
0 to 9999.999m is in the input range.
Order
062

iM-100series-063

Question
Is there space for a pin-pole prism in the case of the iM-105 or iM-101?
Answer
From the November 2018 shipment, the pin pole prism kit can be stored.
Order
063

iM-100series-064

Question
The prism mode is switched in the iM-100 series, but the reflective sheet mode does not appear as an option.
Answer
Check "Target selection" in "Settings -Observation Conditions -Target" settings. If the "Sheet" is set, the reflective sheet mode will not be displayed in the options.
Order
064

iM-100series-065

Question
Is there a laser centripetal option in the iM-100 series?
Answer
It is prepared as an option. The product name will be LP-A-Kit for GM/iM.
Order
065

iM-100series-067

Question
In the iM-100 series, please tell me how to observe the coordinates of new points while piling.
Answer
Press the [F4] measurement on the stake-out observation screen. After the distance measurement, the front, back, left and right are displayed to the piles, and when you press [F1], the displayed coordinates become new coordinates. Enter the name and press [F4] OK to record. If you do not record, go back with [ESC].
Order
067

iM-100series-068

Question
How many job sites can be registered in the iM-100 series?
Answer
Up to 99 sites can be registered.
Order
068

iM-100series-069

Question
Can iM-100 area calculations be used to calculate slant and horizontal areas?
Answer
Both can be done. displayed at the same time when performing area calculations.
Order
069

iM-100series-071

Question
In the iM-100 series, the slope distance is displayed correctly, but the value of the horizontal distance and the height difference is strange, what is the cause?
Answer
Since the V manual is ants, the vertical angle is not set correctly. Set the pear in the following procedure and turn on the power again. Settings → instrument settings → instruments → V manual → No
Order
071

iM-100series-072

Question
Can the iM-100 series and CX series silence the beeping sound when connected via Bluetooth?
Answer
The iM-100 series can mute the sound with the volume setting. The CX series does not have a volume setting, so the sound cannot be muted.
Order
072

iM-100series-073

Question
"Resection" measurement inputs 4 digits decimal in the N coordinate, but does not proceed.
Answer
The coordinates must be entered up to 3 digits decimal.
Order
073

iM-100series-075

Question
In the iM-100 series, when the coordinates are read with the reading button, the point name is displayed without the Z coordinates. Please tell me how to check the coordinates.
Answer
Focus on the Y coordinate, press the right or left button, and press the down button to display the Z coordinate.
Order
075