FXseries-001
- Question
-
While using FX, the message "Port opening failed" appeared.
- Answer
-
Turn off the instrument and reset it (turn it on while holding down the Enter key).
- Order
-
001
FXseries-007
- Question
-
Is there any way to make the alphabet capitalized?
- Answer
-
Switch characters with the [α] key, press and hold the [Shift] key to switch lowercase and uppercase letters.
- Order
-
007
FXseries-008
- Question
-
Data has been erased, but can it be recovered?
- Answer
-
Not possible.
- Order
-
008
FXseries-009
- Question
-
The password was not set, but the screen came out.
- Answer
-
It cannot be used until the correct password is entered.
To unlock the device, it is necessary to send the instrument to the purchasing company.
- Order
-
009
FXseries-010
- Question
-
FX series prism constants, How to change the prism constants?
- Answer
-
Change with "Target" of "EDM setting" in "Settings".
- Order
-
010
FXseries-011
- Question
-
Distance resolution: Is there a 0.1mm setting? (FX series)
- Answer
-
It is not used in the FX series. It is used in SX, DX, and iX.
- Order
-
011
FXseries-012
- Question
-
Can the battery BDC72 be used with the FX series instead of BDC70?
- Answer
-
Can be used. The charger for BDC72 is CDC77.
- Order
-
012
FXseries-013
- Question
-
Why does the FX series shift about 1' when measuring just above zenith?
- Answer
-
Near the zenith and directly below, the tilt correction is cut off, so the tilt of the instrument will appear as it is. Align the center with the electronic bubble tube on the screen.
- Order
-
013